Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
Mikrochim Acta ; 191(4): 228, 2024 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-38558104

RESUMO

A cutting-edge electrochemical method is presented for precise quantification of amitraz (AMZ), a commonly used acaricide in veterinary medicine and agriculture. Leveraging a lab-made screen-printed carbon electrode modified with a synergistic blend of perylene tetracarboxylic acid (PTCA), mesoporous carbon (MC), and Nafion, the sensor's sensitivity was significantly improved. Fine-tuning of PTCA, MC, and Nafion ratios, alongside optimization of the pH of the supporting electrolyte and accumulation time, resulted in remarkable sensitivity enhancements. The sensor exhibited a linear response within the concentration range 0.01 to 0.70 µg mL-1, boasting an exceptionally low limit of detection of 0.002 µg mL-1 and a limit of quantification of 0.10 µg mL-1, surpassing maximum residue levels permitted in honey, tomato, and longan samples. Validation with real samples demonstrated high recoveries ranging from 80.8 to 104.8%, with a relative standard deviation below 10%, affirming the method's robustness and precision. The modified PTCA/MC/Nafion@SPCE-based electrochemical sensor not only offers superior sensitivity but also simplicity and cost-effectiveness, making it a pivotal tool for accurate AMZ detection in food samples. Furthermore, beyond the scope of this study, the sensor presents promising prospects for wider application across various electrochemical analytical fields, thereby significantly contributing to food safety and advancing agricultural practices.


Assuntos
Carbono , Polímeros de Fluorcarboneto , Perileno , Toluidinas , Carbono/química , Perileno/química , Eletrodos
2.
J Mater Chem B ; 12(12): 2950-2984, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38426529

RESUMO

Thin-film nano-architecting is a promising approach that controls the properties of nanoscale surfaces to increase their interdisciplinary applications in a variety of fields. In this context, zinc oxide (ZnO)-based various nano-architectures (0-3D) such as quantum dots, nanorods/nanotubes, nanothin films, tetrapods, nanoflowers, hollow structures, etc. have been extensively researched by the scientific community in the past decade. Owing to its unique surface charge transport properties, optoelectronic properties and reported biomedical applications, ZnO has been considered as one of the most important futuristic bio-nanomaterials. This review is focused on the design/synthesis and engineering of 0-3D nano-architecture ZnO-based thin films and coatings with tunable characteristics for multifunctional biomedical applications. Although ZnO has been extensively researched, ZnO thin films composed of 0-3D nanoarchitectures with promising thin film device bio-nanotechnology applications have rarely been reviewed. The current review focuses on important details about the technologies used to make ZnO-based thin films, as well as the customization of properties related to bioactivities, characterization, and device fabrication for modern biomedical uses that are relevant. It features biosensing, tissue engineering/wound healing, antibacterial, antiviral, and anticancer activity, as well as biomedical diagnosis and therapy with an emphasis on a better understanding of the mechanisms of action. Eventually, key issues, experimental parameters and factors, open challenges, etc. in thin film device fabrications and applications, and future prospects will be discussed, followed by a summary and conclusion.


Assuntos
Nanoestruturas , Nanotubos , Óxido de Zinco , Óxido de Zinco/química , Nanotecnologia , Nanotubos/química , Nanoestruturas/química , Propriedades de Superfície
3.
Food Chem ; 439: 138147, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38070230

RESUMO

A label-free electrochemical immunosensor using a toluidine blue (TB)/porous organic polymer (POP)/two-dimensional molybdenum diselenide (2D MoSe2) nanocomposite is developed for highly sensitive detection of aflatoxin B1 (AFB1) in selected crops. A POP/2D MoSe2 composite material is employed to modify the surface of a screen-printed carbon electrode (SPCE). Subsequently, TB is adsorbed on the modified SPCE surface, and the resulting TB/POP/2D MoSe2 composite is then used to construct a biosensor. The new POP/2D MoSe2 nanocomposite offers a high surface-to-volume area and is a good electroactive and biocompatible adsorbent for loading TB probe and capture antibodies. Adsorbed TB onto the POP/2D MoSe2 nanocomposite is utilized as a redox probe for the signal amplification unit. This TB/POP/2D MoSe2 nanocomposite provides good electron transfer properties of TB redox probe, good electrical conductivity, good biocompatibility, and likable adsorption ability, thus obtaining a sufficient immobilization quantity of antibodies for the sensor construction. After immobilization of the anti-AFB1 antibody and blocking with BSA on the composite surface, the immunosensor is obtained for the detection of AFB1. Under optimum conditions, the sensor shows a linear logarithmic range of 2.5-40 ng mL-1 with a limit of detection (LOD) of 0.40 ng mL-1. The developed sensor provides several advantages in terms of simplicity, low cost, short analysis time, high selectivity, stability, and reproducibility. Additionally, the proposed immunosensor is successfully validated by the detection of AFB1 in rice, corn, and peanut samples. Utilizing the TB/POP/2D MoSe2 nanocomposite, this label-free electrochemical immunosensor demonstrates outstanding sensitivity and selectivity in detecting AFB1, making it a valuable tool for ensuring the safety of agricultural products and enhancing food security.


Assuntos
Técnicas Biossensoriais , Nanocompostos , Aflatoxina B1/análise , Cloreto de Tolônio , Polímeros , Técnicas Biossensoriais/métodos , Porosidade , Reprodutibilidade dos Testes , Imunoensaio/métodos , Carbono/química , Anticorpos , Produtos Agrícolas , Nanocompostos/química , Técnicas Eletroquímicas/métodos , Limite de Detecção , Ouro/química
4.
J Cell Biochem ; 124(10): 1546-1556, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37665725

RESUMO

Fucosylated alpha-fetoprotein (AFP-L3) is a more specific and sensitive biomarker for early diagnosis of hepatocellular carcinoma (HCC) than only the alpha-fetoprotein (AFP) level. Rapid and simple detection of AFP-L3 level greatly facilitates the early detection as well as the treatment of HCC, resulting in the reduction of mortality. Here, we developed a rapid and sensitive lateral flow assay (LFA) using lectin Lens culinaris agglutinin (LCA), which has a specific affinity to AFP-L3 fraction of AFP, as a biorecognition element for determination of the fucosylation of AFP. The assay is based on a sandwich format performed on a lateral flow test strip. LCA was immobilized on the membrane as a test line (T). Quantitative detection of AFP-L3 was achieved by measuring the green color intensity of captured gold nanoparticle conjugates on the T and control line (C) utilizing an in-house test strip reader. The calculated absorbance obtained by the green color intensity signals proportionally increased with AFP concentrations. The developed lectin-based LFA provided a detection limit of 0.8 ng/mL for AFP with a linear range between 1.5 and 160.0 ng/mL within an assay time of 10 min. Recoveries between 74.5% and 113.2% with relative standard deviations of 5.2%-8.7% for measuring spiked human serum were also achieved. The results reveal that the proposed assay offers a rapid, sensitive, and specific method, which is useful for development in point-of-care testing for early detection and treatment of HCC.

5.
Front Bioeng Biotechnol ; 11: 1182880, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37284243

RESUMO

The quantification of alpha-fetoprotein (AFP) as a potential liver cancer biomarker which is generally found in ultratrace level is of significance in biomedical diagnostics. Therefore, it is challenging to find a strategy to fabricate a highly sensitive electrochemical device towards AFP detection through electrode modification for signal generation and amplification. This work shows the construction of a simple, reliable, highly sensitive, and label-free aptasensor based on polyethyleneimine-coated gold nanoparticles (PEI-AuNPs). A disposable ItalSens screen-printed electrode (SPE) is employed for fabricating the sensor by successive modifying with PEI-AuNPs, aptamer, bovine serum albumin (BSA), and toluidine blue (TB), respectively. The AFP assay is easily performed when the electrode is inserted into a small Sensit/Smart potentiostat connected to a smartphone. The readout signal of the aptasensor derives from the electrochemical response of TB intercalating into the aptamer-modified electrode after binding with the target. The decrease in current response of the proposed sensor is proportional to the AFP concentration due to the restriction of the electron transfer pathway of TB by a number of insulating AFP/aptamer complexes on the electrode surface. PEI-AuNPs improve SPE's reactivity and provide a large surface area for aptamer immobilization whereas aptamer provides selectivity to the target AFP. Consequently, this electrochemical biosensor is highly sensitive and selective for AFP analysis. The developed assay reveals a linear range of detection from 10 to 50000 pg mL-1 with R 2 = 0.9977 and provided a limit of detection (LOD) of 9.5 pg mL-1 in human serum. With its simplicity and robustness, it is anticipated that this electrochemical-based aptasensor will be a benefit for the clinical diagnosis of liver cancer and further developed for other biomarkers analysis.

6.
RSC Adv ; 13(21): 14078-14088, 2023 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-37197673

RESUMO

The study aimed to investigate the effects of two different plasma systems, including pinhole plasma jet and gliding arc (GA) plasma, for the degradation of herbicide, diuron, in plasma activated solutions (PAS). In the GA plasma system, air was used to generate plasma, however, Ar, oxygen and nitrogen at different gas compositions were compared in the pinhole plasma jet system. The Taguchi design model was used to study the effects of gas compositions. Results revealed that the pinhole plasma jet system was able to degrade over 50% of the diuron in 60 minutes. The optimal plasma generation condition for the highest degradation of diuron used pure Ar gas. The highest degradation percentage of herbicide in PAS corresponded to the lowest hydrogen peroxide (H2O2) content, nitrite concentration and electrical conductivity (EC) of the PAS. The diuron degradation products were identified as 3,4-dichloro-benzenamine, 1-chloro-3-isocyanato-benzene and 1-chloro-4-isocyanato-benzene via gas chromatography-mass spectrometry (GC-MS). The GA plasma system was not adequate for the degradation of herbicide in PAS.

7.
ACS Omega ; 8(20): 17932-17940, 2023 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-37251123

RESUMO

Human immunodeficiency virus (HIV) causing acquired immune deficiency syndrome (AIDS) is still a global issue. Long-term drug treatment and nonadherence to medication increase the spread of drug-resistant HIV strains. Therefore, the identification of new lead compounds is being investigated and is highly desirable. Nevertheless, a process generally necessitates a significant budget and human resources. In this study, a simple biosensor platform for semi-quantification and verification of the potency of HIV protease inhibitors (PIs) based on electrochemically detecting the cleavage activity of the HIV-1 subtype C-PR (C-SA HIV-1 PR) was proposed. An electrochemical biosensor was fabricated by immobilizing His6-matrix-capsid (H6MA-CA) on the electrode surface via the chelation to Ni2+-nitrilotriacetic acid (NTA) functionalized GO. The functional groups and the characteristics of modified screen-printed carbon electrodes (SPCE) were characterized by Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDS). C-SA HIV-1 PR activity and the effect of PIs were validated by recording changes in electrical current signals of the ferri/ferrocyanide redox probe. The detection of PIs, i.e., lopinavir (LPV) and indinavir (IDV), toward the HIV protease was confirmed by the decrease in the current signals in a dose-dependent manner. In addition, our developed biosensor demonstrates the ability to distinguish the potency of two PIs to inhibit C-SA HIV-1 PR activities. We anticipated that this low-cost electrochemical biosensor would increase the efficiency of the lead compound screening process and accelerate the discovery and development of new HIV drugs.

8.
Talanta ; 258: 124472, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37013336

RESUMO

We developed a novel, sensitive, and selective platform for the specific determination of aflatoxin B1 (AFB1). Single-walled carbon nanohorns decorated by a cobalt oxide composite and gold nanoparticles were created to provide facile electron transfer and improve the sensor's sensitivity. In addition, we attributed the selectivity of the proposed sensor to the specific binding property of the anti-aflatoxin B1 antibody. We clarified the specific interaction of the proposed immunosensor to AFB1 using homology modeling combined with molecular docking. In the presence of AFB1, the current signal of the modified electrode reduced; this involved specific antibody-antigen binding, including hydrophobic hydrogen bonding and pi-pi stack interactions. The new AFB1 sensor platform showed two linearity ranges of 0.01-1 ng mL-1 and 1-100 ng mL-1, with the limit of detection at 0.0019 ng mL-1. We investigated the proposed immunosensor in real samples, including peanuts, certified reference material of a peanut sample (labeled 206 µg kg-1 AFB1), corn, and chicken feed. The sensor's accuracy was 86.1-104.4% recovery, which agrees with the reference HPLC technique using paired t-test analysis. The present work shows excellent performance for AFB1 detection and could be applied for food quality control or modified to detect other mycotoxins.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Técnicas Biossensoriais/métodos , Aflatoxina B1/análise , Aflatoxina B1/química , Nanocompostos/química , Imunoensaio/métodos , Ouro/química , Carbono/química
9.
J Anal Methods Chem ; 2023: 3400863, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36687006

RESUMO

The miniaturization of analytical systems and the utilization of nontoxic natural extract from plants play significant roles for green analytical chemistry methodology. In this work, the microfluidic hydrodynamic sequential injection (HSI) with the LED-phototransistor colorimetric detection system has been proposed to create an ecofriendly and low-cost miniaturized analytical system for online determination of iron in water samples using Curcuma putii Maknoi & Jenjitt. extracts as high stability and good selectivity of a natural reagent. The proposed method was designed for online solution mixing and colorimetric detection on a microfluidic platform. The Curcuma putii Maknoi & Jenjitt. extracts and standard/samples were sequentially aspirated to fill the channel before entering the built-in flow cell. The intensity of iron-Curcuma putii Maknoi & Jenjitt. extract complex was monitored under the optimum conditions of flow rate, sample volume, mixing zone length, and aspiration sequences, by altering the gain control of the colorimetric detector to achieve good sensitivity. The results demonstrated a good performance of the green analytical systems. A linear calibration graph in the range of 0.5-6.0 mg L-1 was obtained with a limit of detection at an adequate level of 0.11 mg L-1 for water samples with a sample throughput of 30 h-1. The precise and accurate measurement results were achieved with relative standard deviations in the range of 1.61-1.72%, and percent recoveries were found in the range of 90.6-113.4. The proposed method offers cost-effective, easy operation over an appropriate analysis time (2 min/injection) with good sensitivity and is environmentally friendly with low consumption of solutions and the use of high stability and good selectivity of nontoxic reagents. The achieved method was demonstrated to be a good choice for routine analysis.

10.
Front Cell Infect Microbiol ; 12: 916357, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36389169

RESUMO

Liver cancer is one of the most common global health problems that features a high mortality rate. Alpha-fetoprotein (AFP) is a potential liver cancer biomarker for the diagnosis of liver cancer. The quantitative detection of AFP at an ultratrace level has important medical significance. Using the reaction of the antibody-antigen pair in an immunosensor enables the sensitive and selective AFP assay. Finding a strategy in signal generation and amplification is challenging to fabricate new sensitive electrochemical immunosensors for AFP detection. This study demonstrates the construction of a simple, reliable, and label-free immunosensor for the detection of AFP on a smart phone. Exfoliated two-dimensional (2D) molybdenum diselenide (MoSe2) and 2D tungsten diselenide (WSe2) were employed to modify the disposable screen-printed carbon electrode (SPCE) to use as the electrochemical platform, which is affixed to a small potentiostat connected to a smart phone. The modified electrode offers antibody immobilization and allows detection of AFP via an immunocomplex forming a sandwich-like configuration with the AFP-corresponding aptamer. A heterojunction 2D MoSe2/2D WSe2 composite improves the SPCE's reactivity and provides a large surface area and good adsorption capacity for the immobilizing antibodies. The signal generation for the immunosensor is from the electrochemical response of methylene blue (MB) intercalating into the aptamer bound on the electrode. The response for the proposed sandwich-like immunosensor is proportional to the AFP concentration (1.0-50,000 pg ml-1). The biosensor has potential for the development of a simple and robust point-of-care diagnostic platform for the clinical diagnosis of liver cancer, achieving a low limit of detection (0.85 pg ml-1), high sensitivity, high selectivity, good stability, and excellent reproducibility.


Assuntos
Técnicas Biossensoriais , Neoplasias Hepáticas , Humanos , alfa-Fetoproteínas , Imunoensaio/métodos , Técnicas Biossensoriais/métodos , Azul de Metileno , Reprodutibilidade dos Testes , Ouro , Técnicas Eletroquímicas/métodos , Eletrodos , Anticorpos , Neoplasias Hepáticas/diagnóstico
11.
Inorg Chem ; 61(48): 19612-19623, 2022 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-36383774

RESUMO

Fabrication of a new three-dimensional Cu(II) metal-organic framework, {[Cu4(4,4'-bipy)3(OH)2(mal)3]·4H2O}n (1a; 4,4'-bipy = 4,4'-bipyridine, H2mal = malonic acid; P21/m), that undergoes an unprecedented redox-versatile ligand-substitution-induced single-crystal to single-crystal transformation, for smartphone-based detection of iodide was studied. The Cu-MOF 1a has been effortlessly synthesized by the microwave-heating technique. Phase formation of the Cu-MOF 1a depended on counter-anions. The transformations can be triggered by halides to corresponding coordination polymers through both non-redox and redox-associated pathways. The changes in the local structure and oxidation state of copper during the transformation were studied by ex situ and in situ synchrotron X-ray absorption spectroscopies. The selectivity of the halide-triggered transformation was investigated. A study on smartphone-based colorimetric detection of iodide was found to be linearly proportional to the iodide concentration in the range 10-1500 mg/L with a limit of detection of 5 mg/L and good precision relative standard deviation of 1.9% (n = 11), possibly to construct the iodide test kit.


Assuntos
Colorimetria , Iodetos , Ligantes , Estrutura Molecular , Cristalografia por Raios X , Smartphone , Modelos Moleculares
12.
ACS Omega ; 7(21): 17741-17755, 2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35664576

RESUMO

Pd-based catalysts consisting of Pd nanoparticles on nitrogen-doped carbon quantum dots (N-CQDs) modified silica (SiO2) and reduced graphene oxide have been synthesized through reduction for use as catalysts for improved formic acid oxidation. The structure, morphology, chemical composition, functional groups, and porosity of the synthesized catalysts were characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), Fourier transform infrared (FT-IR) spectroscopy, Raman spectroscopy, and Brunauer-Emmett-Teller (BET) spectroscopy, respectively. Their electrocatalytic activities were also evaluated by electrochemical measurements. The differences in the average particle sizes found for Pd/N-CQDs-SiO2-rGO, Pd/N-CQDs-rGO, and Pd/rGO were 4.81, 5.56, and 6.31 nm, respectively. It was also found that the Pd/xN-CQDs-SiO2-yrGO composite catalysts (where x and y is 1 to 4) can significantly improve the activity and stability toward formic acid electrooxidation compared with Pd/rGO and commercial Pt/C. The mass activities of Pd/N-CQDs-SiO2-rGO, Pd/N-CQDs-rGO, and Pd/rGO were 951.4, 607.8, and 157.6 mA g-1, respectively, which was ca. 6-7 times compared with Pd/rGO and approximately 3-4 times compared with commercial Pt/C. With low potential for CO oxidation and high current intensity, the composites of rGO, SiO2, and N-CQDs into Pd-based catalysts improved the catalytic activity of the prepared catalyst for the oxidation of formic acid in acidic media. The value of the Tafel slope designated that the chief path of the prepared catalysts is the dehydrogenation process. These prepared catalysts exhibit promise toward the development of high-performance Pd-based electrocatalysts for formic acid oxidation.

13.
Analyst ; 147(10): 2170-2179, 2022 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-35441623

RESUMO

A portable paper-based electrochemical sensor has been developed to determine 5-hydroxymethylfurfural (5-HMF). A screen-printed carbon electrode (SPCE) was facilely fabricated for the first time on poster paper which showed a very satisfactory electrochemical response. The analytical performance of the electrode was enhanced by electrochemical deposition of silver microdendrites (AgMDs). The cathodic peak of 5-HMF occurred at approximately -1.48 V, lower than that obtained from the bare poster-SPCE. Moreover, the modified electrode showed a higher current response than the bare electrode, revealing that the AgMDs not only exhibited highlighted electrocatalytic features but also improved the electrical conductivity and increased the electrode surface area. Afterward, some influencing conditions were optimized, including scan rate and the number of scan cycles for AgMD deposition, pH, temperature, and square wave voltammetric parameters. Under the optimal conditions, the analytical characteristics of the proposed sensor were evaluated. The cathodic peak current increased linearly according to 5-HMF concentration over the range of 3-100 ppm, and the detection limit was 1.0 ppm. This low-cost, disposable electrochemical sensor provided environmentally friendly, simple and rapid detection, acceptable precision, good stability, and high selectivity. Additionally, this method can be applied to quantify 5-HMF in honey samples with satisfying accuracy.


Assuntos
Técnicas Eletroquímicas , Prata , Carbono , Técnicas Eletroquímicas/métodos , Eletrodos , Furaldeído/análogos & derivados
14.
Food Chem ; 382: 132055, 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35255354

RESUMO

This work aims to develop a more robust, easy-to-use, low-pressure, and cost-effective nonsuppressed open tubular capillary ion chromatography (NS-OTIC) approach with online dialysis for small ions determination in drinks. The fabricated device was applied for two selected columns, including poly(butadiene-maleic acid) on a 50-µm bore and AS18 Latex on 25-µm bore fused silica capillaries, for the separation of mixed cations (Na+, K+, Ca2+, Mg2+) and mixed anions (Cl-, Br-, NO2-, NO3-), respectively. High concentrations of ions (up to 100 mM) level can be directly introduced into the NS-OTIC system without an off-line (manual) dilution step. The linear relationship of the peak area and concentration of model ions can be obtained with a resolution > 1.1. The repeatability of the peak area for both OTIC columns was < 6% RSD. Juice and tea samples were successfully analyzed with % recoveries of 77-112 and 90-119 for cation and anion determinations, respectively.


Assuntos
Diálise Renal , Dióxido de Silício , Ânions/análise , Cátions/análise , Cromatografia por Troca Iônica/métodos
15.
Colloids Surf B Biointerfaces ; 210: 112260, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34894598

RESUMO

A dual-mode electrochemical biosensor is successfully developed for simultaneous detection of two different kinds of breast cancer biomarkers, namely cancer antigen 15-3 (CA 15-3) and microRNA-21 (miRNA-21), for the first time. The sensor composes of a poly(3-aminobenzylamine)/two-dimensional (2D) molybdenum selenide/graphene oxide nanocomposite modified two-screen-printed carbon electrode array (dual electrode), functionalized individually with 2,3-diaminophenazine-gold nanoparticles and toluidine blue-gold nanoparticles. Both kinds of the redox probe-gold nanoparticles are employed as signaling molecules and supports for immobilization of anti-CA 15-3 antibodies and capture DNA-21 probes, respectively. Due to the good conductivity and high surface-to-volume ratio of the nanocomposite, high amount of the antibodies and capture probes can be immobilized on the modified dual-electrode, giving the efficient duplex detection. Consequently, the biosensor provides good selectivity, and high sensitivity for the dual target analyte detection. The experimental results show that this label-free biosensor exhibits good linear responses to the concentrations of both target analytes with the limits of detection (LODs) of 0.14 U mL-1 and 1.2 fM for CA 15-3 and miRNA-21, respectively. This assay strategy has a great potential to be further developed for the simultaneous detection of a variety of miRNAs and protein biomarkers for point-of-care (POC) diagnostic applications.


Assuntos
Técnicas Biossensoriais , Neoplasias da Mama , Grafite , Nanopartículas Metálicas , MicroRNAs , Mucina-1 , Biomarcadores Tumorais , Técnicas Eletroquímicas , Eletrodos , Feminino , Ouro , Humanos , Limite de Detecção
16.
Bioelectrochemistry ; 142: 107944, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34500138

RESUMO

Methylene blue (MB) adsorption onto a two-dimensional molybdenum disulfide (2D MoS2)/graphene oxide (GO) nanocomposite sitting on a screen-printed carbon electrode (SPCE) is used to develop a new sensitive label-free electrochemical immunosensor for the detection of matrix metalloproteinase-7 (MMP-7) cancer biomarkers. The 2D MoS2/GO nanocomposite deposited onto an SPCE provides a large specific surface area, fast electron transfer, and exceptional electrical conductivity. Furthermore, MB adsorbed onto the 2D MoS2/GO nanocomposite architecture can be used for signal amplification in electrochemical immunosensors. Moreover, an immunosensor platform was fabricated by the adsorption of anti-MMP-7 capture antibodies onto the MB/2D MoS2/GO nanocomposite surface via electrostatic interactions for the detection of the MMP-7 immunocomplex. Under optimum conditions, the label-free immunosensor exhibits a decrease in the current response for MB corresponding to the MMP-7 concentration. The sensor affords a linear logarithmic range of 0.010-75 ng mL-1 with a limit of detection (LOD) of 0.007 ng mL-1. The developed electrochemical immunosensor provides high selectivity, good reproducibility, and excellent stability. Furthermore, the proposed immunosensor can be applied for the detection of MMP-7 in human serum samples with good recovery. Thus, this device can be applied for the early clinical diagnosis of pancreatic and colorectal cancers.


Assuntos
Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Imunoensaio/métodos , Metaloproteinase 7 da Matriz/sangue , Dissulfetos/química , Grafite/química , Humanos , Azul de Metileno/química , Molibdênio/química
17.
Analyst ; 146(15): 4848-4857, 2021 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-34231560

RESUMO

A colorimetric aptasensor for chlorpyrifos detection utilizing the localized surface plasmon resonance (LSPR) of gold nanoparticle (AuNP) aggregates coupling with a specific aptamer and cationic polyethyleneimine (PEI) has been developed. The measurement principle is based on a remarkable characteristic of AuNPs that can change their colors under the aggregation and dispersion conditions, which enables a sensitive colorimetric detection. In the absence of chlorpyrifos, negatively charged phosphate backbones of the aptamer potentially interact with the cationic PEI, resulting in the red color appearance of the dispersed AuNPs, whereas, in the presence of chlorpyrifos, the aptamer binds explicitly to chlorpyrifos, consequently releasing cationic PEI. Uninteracted PEI induces AuNP aggregation, causing a color change from red to blue that can be observed through the naked eye. Under the optimized conditions, 6 nM PEI, 10 nM aptamer, and a pH buffer of 7.5, the colorimetric aptasensor gives a linear response in the range of 20-300 ng mL-1 with a low detection limit of 7.4 ng mL-1. The developed method has been successfully applied to complex sample analysis. The accuracy and precision of chlorpyrifos quantification in spiked samples, including tap water, pomelo, and longan samples, are in the acceptable criteria of method validation, indicating that the developed aptasensor can be utilized as an alternative analytical tool for chlorpyrifos determination in complex samples. This aptasensor provides advantages such as a simple procedure, low cost, short analysis time, and involving uncomplicated instruments. Moreover, it offers high sensitivity, selectivity, and stability.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Clorpirifos , Nanopartículas Metálicas , Colorimetria , Ouro , Polietilenoimina
18.
Anal Sci ; 37(12): 1825-1828, 2021 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-34219117

RESUMO

A cost-effective long-path absorption liquid core waveguide (LCW) device was fabricated from a typical Teflon tube, and using a high refractive index (RI) medium of acid. It was incorporated in a flow injection-gas diffusion system for the sensitive determination of sulfide via methylene blue (MB) chemistry. The gas diffusion unit could prevent some interferences in samples. The limit of detection of 0.13 µmol L-1 was achieved without using a preconcentration procedure. The proposed device was successfully applied for sulfide determination in canal water samples with 88.7 - 103% recovery.


Assuntos
Colorimetria , Sulfetos , Análise Custo-Benefício , Difusão , Indicadores e Reagentes
19.
Sci Rep ; 11(1): 13969, 2021 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-34234187

RESUMO

A label-free electrochemical aptamer-based sensor has been fabricated for alpha-fetoprotein (AFP) detection. Platinum nanoparticles on carboxylated-graphene oxide (PtNPs/GO-COOH) modified screen-printed graphene-carbon paste electrode (SPGE) was utilized as an immobilization platform, and the AFP aptamer was employed as a bio-recognition element. The synthesized GO-COOH helps to increase the surface area and amounts of the immobilized aptamer. Subsequently, PtNPs are decorated on GO-COOH to enhance electrical conductivity and an oxidation current of the hydroquinone electrochemical probe. The aptamer selectively interacts with AFP, causing a decrease in the peak current of the hydroquinone because the binding biomolecules on the electrode surface hinder the electron transfer of the redox probe. Effects of aptamer concentration and AFP incubation time were studied, and the current changes of the redox probe before and after AFP binding were investigated by square wave voltammetry. The developed aptasensor provides a linear range from 3.0-30 ng mL-1 with a detection limit of 1.22 ng mL-1. Moreover, the aptamer immobilized electrode offers high selectivity to AFP molecules, good stability, and sensitive determination of AFP in human serum samples with high recoveries.

20.
Anal Methods ; 13(30): 3348-3358, 2021 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-34286735

RESUMO

In this research, the pH differential method was explored for the first time using a mobile phone as a detector, replacing UV-Vis spectrophotometry. A smartphone digital image colorimetric (SDIC) system was developed for the determination of the total monomeric anthocyanin content in black rice grains using colour values. The change in colour of anthocyanin cyanidin-3-glucoside (C3G) at pH 1.0 and pH 4.5 was investigated and described through colour model systems (RGB and CIELAB). Under optimum conditions, the quantitative method based on the chroma difference, was able to quantify the total amount of monomeric anthocyanins with a linear correlation (R2 = 0.989) to that of UV-Vis spectrophotometry and high performance liquid chromatography (HPLC) (reference method). The SDIC system displayed good precision (≤1.88% RSD) and a low detection limit (2.2 ± 0.1 µg g-1). The validated results demonstrated that the developed method was a cost-effective alternative for the quantitation of anthocyanins. In addition, the effect of six mineral elements on black rice cultivation was investigated. The results showed that the addition of the Ca fertiliser resulted in black rice grains with an anthocyanin content 2-fold higher than that of the control with a significant difference (p < 0.05).


Assuntos
Antocianinas , Oryza , Colorimetria , Concentração de Íons de Hidrogênio , Smartphone
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...